MonnitLink
Ethernet Gateway Quick Start
• Create a Monnit user account with assigned wireless gateways and sensors.
Attach the antenna to the antenna connector on the back panel of the Ethernet gateway
(make sure the connection is snug, but do not overtighten).
• Plug an Ethernet cable with internet connectivity into the gateway.
• Plug the power supply into a power outlet then connect to the gateway.
• Once all three lights turn green, your network is ready to bring sensors online.
Monnit Wireless Sensors
and Ethernet Gateway
Users Guide
For Use With iMonnit Online Software
and iMonnit Express PC Software
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - User’s Guide

MonnitLink™ Ethernet Gateway Quick Start • Create a Monnit user account with assigned wireless gateways and sensors. • Attach the antenna to t

Seite 2 - Back of Sensor

PAGE 10Devices to NotifyIf you have a Monnit Control or Notier A/V device on your network, you will also see a “Devices to Notify” tab. This will all

Seite 3 - Ethernet Gateway

6. Calibrating Sensor DataCertain wireless sensors can be calibrated for more accurate readings (ex. temperature sensors). If calibration is possible

Seite 4

PAGE 125. Advanced Settings and Interfacing with the Monnit Ethernet Gateway Through iMonnit.1. Ethernet Gateway Edit ScreenWhen you log into the

Seite 5 - 4. Using The iMonnit

To set the Static IP, uncheck the Use DHCP box and ll in the settings:The force transmit on Aware box tells the gateway to deliver immediately the me

Seite 6

PAGE 14MODBUS TCP InterfaceUse MODBUS TCP software to pull in gateway and sensor data. Monnit provides a register map. Check the box to make the inter

Seite 7

Data 1 Sensor Data Field 1 40109 108 Data 2 Sensor Data Field 2 40110 109 Data 3 Sensor Data Field 3 40111 110 Data 4 Sensor Data Field 4 40112 111 D

Seite 8 - Notication

PAGE 16Ethernet Gateway MIB tree with a short description of each eld:EGW Data Description*GW Section Gateway Section*GW Serial Gateway Serial ID*Ver

Seite 9

6. Setting up the Ethernet gateway for use with iMonnit ExpressiMonnit Express (PC Software) SetupVisit http://www.monnit.com/support/downloads/ to do

Seite 10

PAGE 18• Click on “About”, then “Local IP Addresses” and make note of the IP address that your computer is using on your network. • Connect

Seite 11

• When nished, click the “Reboot” button on the top right side of the page to restart the gateway. • When the lights begin ashing on the gatewa

Seite 12 - Gateway Through iMonnit

1. Create a Monnit User Account and Setup Sensor Network If this is your rst time using the iMonnit online system site, you will need to create a ne

Seite 13

Error Reporting, Troubleshooting and Support For technical support and troubleshooting tips please visit our support library online at http://www

Seite 14

(b) As a condition to Monnit’s obligations under the immediately preceding paragraphs, Customer shall return Products to be examined and replaced to M

Seite 15

CerticationsUnited States FCC This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 o

Seite 16

PAGE 23Canada (IC) EnglishUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser

Seite 17 - Code: XXXXXX

Monnit Corporation7304 South CottonwoodSuite #204Midvale, Utah 84047801-561-5555www.monnit.comAll trademarks are property of Monnit. © 2009-2014 Mon

Seite 18

PAGE 37. Conrmation Screen.When you have nished adding the sensor, you will see a conrmation screen. At this point you can assign notications to t

Seite 19

3. Conguring The Ethernet Gateway The Ethernet Gateway collects data from all sensors within range and is precongured to batch deliver the sensor me

Seite 20 - Warranty Information

4. Using The iMonnit™ Online Wireless Sensor System1. Understanding The Online InterfaceWhen you log into the online system, the default view shows al

Seite 21

PAGE 6To the left side of each sensor row is an indicator to help you understand the current status of the sensor. Sensor is checking in and within us

Seite 22 - Certications

PAGE 73. Conguring Sensor SettingsTo edit a sensors operation settings, click on the sensor overview row to display the de-tails view. Click on the “

Seite 23 - Canada (IC)

4. Sensor and/or Gateway Notication(s).Notications for a single sensor can be created, deleted or edited by clicking the “Notications” tab in a sen

Seite 24

• Advanced Notications - Allows the user to set notications based on advanced rules, such as comparing past data points with the current one to det